The compact EP LMF®-System:

  • BASIC

    Designed for integration into existing systems

  • STANDARD

    Ideal for PLC-based plant environments

  • CLASSIC

    Ideal for stand-alone applications in laboratory and industry

Tailor-made solutions for your requirements

Compact system for accurate flow measurement and adjustment


With our new LMF® system (laminar flow system), we offer an exciting pre-configured system variants for precise flow measurement and control. Read about the details and configure your individual laminar flow measurement system with our LMF®-Configuration tool.

  • Fast and accurate measurement
  • Simple handling
  • Modular setup
  • Selectable from three different system con gurations
made We produce and calibrate in Baden-Württemberg

  • BASIC

    EP-µController – designed for integration into existing systems

  • STANDARD

    Siemens-control – ideal for PLC-based plant environments

  • CLASSIC

    Touch Panel-PC (LabVIEW®) – ideal for stand-alone applications in laboratory and industry

BASIC EP-µController – designed for integration into existing systems

  • EP-µController

  • Basic functionality

  • Designed for integration into existing systems

  • Measurement accuracy up to < 0,9% + 0,10 % FS

STANDARD Siemens-control – ideal for PLC-based plant environments

  • Siemens-control

  • PLC-based evaluation unit with reliable technology

  • Ideal for PLC-based plant environments

  • Measurement accuracy up to < 0,7 % + 0,08 % FS

CLASSIC Touch Panel-PC (LabVIEW®) – ideal for stand-alone applications in laboratory and industry

  • Personal computer with touch-panel (LabVIEW®)

  • Windows operation system with EP-software

  • Easy integration into company network

  • Any windows software installable

  • Ideal for stand-alone applications in laboratory and industry

  • Measurement accuracy up to < 0,5 % + 0,06 % FS

LMF®-Configuration tool

Use our configuration tool to configure your individual measurement system with adjusted parameters:

Laminar Flow Elements

Laminar Flow Elements, abbreviated as LFEs, are  ow sensors based on the differential pressure principle. They have been used successfully worldwide by customers for years.

Their operating mode is based on the Hagen– Poiseuille equation, which states that the  ow of a laminar  owing medium is propotional to the pres- sure drop between the beginning and the end of the passed through tube section. Thus results a virtually linear relationship of the LFEs between the  ow and the emerging differential pressure.

Your contact person for Special Solutions

Ehrler Prüftechnik Engineering GmbH
Wilhelm-Hachtel-Straße 8, 97996 Niederstetten

Fon: +49 (0) 7932 / 60 666 46
Fax: +49 (0) 7932 / 60 666 11
E-Mail: E-Mail: info@ep-e.com